High-temperature chemical pump housing in PEEK, tips on avoiding warpage?

0
S
4

Hi everyone, I’m working on a small pump housing for a chemical metering application. The part will be injection molded in PEEK, exposed to roughly 180 °C fluid and aggressive solvents. It’s a compact geometry (80 × 50 × 40 mm), with an internal channel and 3 mm wall thickness, but I’m worried about warpage and stresses. I’ve read that PEEK needs at least 2 mm uniform wall thickness, generous radii, and symmetry to reduce voids and warping, but does anyone have practical experience with these tips on similar parts? Especially in chemical pump housings, what gating strategies, wall tweaks, or cooling methods helped you minimize distortion?

    • S

      Hi everyone, I’m working on a small pump housing for a chemical metering application. The part will be injection molded in PEEK, exposed to roughly 180 °C fluid and aggressive solvents. It’s a compact geometry (80 × 50 × 40 mm), with an internal channel and 3 mm wall thickness, but I’m worried about warpage and stresses. I’ve read that PEEK needs at least 2 mm uniform wall thickness, generous radii, and symmetry to reduce voids and warping, but does anyone have practical experience with these tips on similar parts? Especially in chemical pump housings, what gating strategies, wall tweaks, or cooling methods helped you minimize distortion?

      0
    • R

      Yes, PEEK is tricky. Your 3 mm walls are good; thinner than 2 mm emphasizes voids and knit. Symmetry helps, so keep channels centered and mass balanced for even shrinkage. For something like a pump housing, I’d suggest a valve gate or edge gate feeding from a thicker boss region, not thin walls. Multi-gating = weld lines where you don’t want them. And keep flow paths as short as possible to reduce shear heating.

      0
      Reply
High-temperature chemical pump housing in PEEK, tips on avoiding warpage?
Your information:




Suggested Topics

Topic
Replies
Views
Activity
Process for a low-volume stainless steel pump impeller
Hi all, I’m designing a stainless steel impeller for a small pump (diameter around 80 mm). Would you go for metal additive manufacturing or casting if you need tight tolerances on the blades and... read more
p
0
100
Nov 18
Minimum letter size for raised text on SLS nylon parts
I’m working on a medical device enclosure that needs raised lettering (product name and serial number) on the lid, printed in SLS nylon. The letters are around 2 mm high with a stroke width... read more
m
j
4
415
Oct 30
2 mm stainless sheet bend radius
I’d like some help with a project. I’m designing a stainless steel 304 enclosure with multiple 90° flanges (sheet thickness ~2 mm). For strength and edge alignment, I want the inside bend radius to... read more
L
C
4
307
Oct 24
Urethane casting for sensor housings
Hello all, I’m looking for some advice. I’m working on a prototype of a handheld casing for an outdoor sensor (approx. 20×10×5 cm) that needs to be rigid, weather-resistant, and have fine surface details.... read more
a
e
6
169
Nov 13
Will a threaded hub and locknut hold up in a conveyor roller assembly?
hi! my project is a small conveyor assembly where the rollers need to be swapped out fairly often, depending on the material we’re running. I’m considering using an M14 threaded connection between the aluminum... read more
P
R
4
209
Oct 22